CHECK YOUR PULSE – CHECK YOUR TAGS
and remember to check your safety switches (RCDs)
Pulse Test and Tag have experience in workplace electrical safety standard compliance. Using state of the art equipment our operators provide the best practice testing with best practice reportage. The local Pulse Test and Tag Capalaba area manager is Robert Arcon.
Quotes start from $69.95 + GST inclusive of the first 10 Tags *
Electrical safety is nothing to mess around with; it is the responsibility of the employer; self-employed business owner and supervisor has a duty of care when it comes to electrical safety and compliance.






We will keep you compliant and up to date with your testing and tagging, and RCD (Safety Switch) yearly certificates, before they reach their expiry date.
Our professionally trained technicians are; fully Licensed to Test & Tag in Queensland & Australia with National White Cards, Queensland Blue Cards and Police checks.
Robert’s License number for Electrical Testing & Tagging in QLD is 84012
Our services include but not limited to compliance AS/NZS Standard 3760:2022
In Queensland frequency of testing is dependent on the specific industry standards, it is important to make sure you’re not being over serviced, see below for classes of work:
For more detailed information on your requirements visit:

We Service
Alexandra Hills, Birkdale, Capalaba, Cleveland,
Mount Cotton, Ormiston, Capalaba, Sheldon,
Thornlands, Thornside, Victoria Point, Wellington Point,
The Islands:
Coochiemudlo, Karragarra, Lamb, Macleay,
North Stradbroke, Russell.
and all surrounding suburbs.
SERVICES
Construction Work
Testing & Tagging quarterly at least
Portable RCD: Inbuilt test button immediately before use each time
Portable RCD: Operating Time Current Test at least quarterly
Fixed RCD: Inbuilt test button at least monthly
Fixed RCD: Operating Time Current Test at least annually


Manufacturing Work
Testing & Tagging at least 12 Monthly for double insulated (Class 2) equipment
Testing & Tagging at least 6 Monthly for non-double insulated (Class 1) equipment
Portable RCD: Inbuilt test button immediately before use each time
Portable RCD: Operating Time Current Test at least 12 Monthly
Fixed RCD: Inbuilt test button at least 6 monthly
Fixed RCD: Operating Time Current Test at least 12 Monthly
Service Work
Testing & Tagging at least 12 Monthly, or connected to a Safety Switch
Portable RCD: Inbuilt test button at least 3 monthly
Portable RCD: Operating Time Current Test at least 12 monthly
Fixed RCD: Inbuilt test button at least 3 monthly
Fixed RCD: Operating Time Current Test and least 24 monthly


Office Work
Testing & Tagging at least 60 Monthly, or connected to a safety switch
Portable RCD: Inbuilt test button at least 3 monthly
Portable RCD: Operating Time Current Test at least 24 monthly
Fixed RCD: Inbuilt test button at least 6 monthly
Fixed RCD: Operating Time Current Test at least 24 monthly
*Conditions apply – applies to Single Phase Tests in Redland City Council boundary only